OPERATING INSTRUCTIONS

Chemical Connections:

The RL-30 is supplied with integral detergent and
rinse additive pumps and the chemical hoses are
located on the side of the dishmachine.
This machine must be operated with an automatic
detergent feeder and, if applicable, an automatic
chemical sanitizer feeder, including a visual means
to verify that detergents and sanitizers are delivered
or a visual or audible alarm to signal if detergents
and sanitizers are not available for delivery to the
respective washing and sanitizing systems. Please
see instructions for electrical and plumbing connec-
tions located in this manual and in the feeder equip-
ment manual.
Detergent concentration should be between .25%
(.30oz/gal) and .30% (.38oz/gal). Note: Always
consult chemical manufacturer for proper concen-
tration.
Preparing for operation:
Locate the clear chemical pick up tubes on the
side of the unit
Identify the detergent pick up tube (smaller
diameter ID tube) and place it in the container
of commercial liquid detergent.
Place the rinse additive pick up tube (larger
diameter ID tube) in the container of commercial
liquid rinse additive.
Undercounter DOC RL-30 1.0 06
®
PART 3 OPERATING INSTRUCTIONS
Priming the system:
The detergent pump is self priming and runs dur-
ing the rinse/fill cycle. The amount of detergent
dispensed is controlled by the speed of the peri-
staltic pump. This can be adjusted by turning the
control screw under the pump head.
The rinse additive pump is located behind the
front kick panel. The pump is a diaphragm type
pump and can be primed by inserting a screw-
driver into the screw on the front/top of the
pump, turning counter clockwise and then de-
pressing the screw to begin the manual priming.
Make several compressions until you see the
rinse additive solution entering the check valve
on the other side of the pump. The amount of
rinse additive that is added to the system can be
adjusted by turning the screw clockwise to de-
crease and counterclockwise to increase. Once
set the solution is the added automatically to the
rinse system.
12
www.insingermachine.com 800-344-4802
Control screw under
the pump head
Rinse Pump Adjusting
Screw and Prime
Rinse
Pump

Advertisement