Motor Overloads

All motors used on Insinger Machines are provided
with motor overloads. Motor overloads are adjusted
when the machines are factory tested. Should it be
necessary to adjust the motor overloads in the field
first verify the motor current draw for the voltage
the machine is using.
Using the Control Panel Component Layout Dwg.
located in Section 3 to identify the overload adjust
by turning the dial to the appropriate AMP draw.
Admiral Series DOC ADM-ES 1.0 04
PART 5 MAINTENANCE & REPAIR PROCEDURES
Level System
The level control system consists of one overfill
timer (P/N DE7-35) and one level float (P/N DEF-
60) per tank.
When the system is powered-up, the tank(s) will
begin to fill (assuming no water is in the tanks).
When the level float is actuated, the overfill timer
begins to time-out and continues the filling process
until the tank(s) is full.
Final Rinse Actuator
The final rinse is actuated by a level located on the
rear wall of the dishwasher near the exit end. When
a rack depresses it a switch is closed and a sole-
noid energized.
The activation of the lever also resets the Energy
Saver Timer (P/N DE7-28). The timer will then start
counting from 0. The timer is adjustable between 0
and 300 seconds (5 minutes). See dwg. 116-145.
þ
þ
20
Liquid Level Timer DE7-35
Sk-4698
NOTE:
The overfill timer MUST be adjusted during
initial start-up. Adjustment depends on water
fill pressure. The water level MUST be 1/4"
below the lip of the overflow tube. Adjust by
increasing or decreasing the potentiometer on
the level timer.
NOTE:
Dirty level floats will cause the tank heat to
energize with no water in the tanks.
LEVEL FLOATS MUST BE CLEANED DAILY.