17 | Inspiration and help
Error message
Service 11
Service 12
Service 13
Service 20.8
Service 28.4
Service 42.1
Service 43.1
Service 46.1
17.5.2
Error messages for gas units
If your unit it connected to the gas supply, the following additional error message could appear. For all error
messages, please contact your RATIONAL Service Partner [} 104]. Always have the serial number of your unit
ready.
Error report
Service 32.1
Service 32.2
Service 32.3
Service 33.1
Service 33.2
Service 33.3
Service 34.32
Service 60
17.5.3
Error messages heating hot air
Error report
Service 20.1
Service 28.1
Service 28.2
Service 34.1
Service 34.2
Service 34.4
106 / 120
Cause
The water intake for the steam generator is
malfunctioning.
The water measurement system is malfunctioning.
Detection of the water level in the steam generator is
malfunctioning.
Temperature probe defective.
Cooking cabinet temperature limit exceeded.
The water supply is malfunctioning.
The internal water supply is not closing.
The water supply is malfunctioning.
Cause
The gas burner is faulty.
Close the shut-off valve on the gas line.
The gas burner is faulty.
Close the shut-off valve on the gas line.
The gas burner is faulty.
Close the shut-off valve on the gas line.
The gas burner is faulty.
Close the shut-off valve on the gas line.
The gas burner is faulty.
Close the shut-off valve on the gas line.
The gas burner is faulty.
Close the shut-off valve on the gas line.
The internal data communication is faulty.
The initialisation of the ignition box is
defective.
Switch the unit off and on again. If the
error is still displayed, call your Service
Partner.
Cause
The temperature probe is defective.
The temperature limit of the steam
generator has been exceeded.
The temperature limit of the cooking
cabinet has been exceeded.
The internal data communication is faulty.
The internal data communication is faulty.
The internal data communication is faulty.
Cooking possible
Yes
Yes
Only hot air mode is available.
Only hot air mode is available.
Only hot air mode is available.
Only hot air mode is available.
Only hot air mode is available.
Yes
Cooking possible
No
No
No
No
No
No
Yes
–
Cooking possible
No
No
No
No
No
No