16 | Inspiration and help
Error message
Service 120
16.5.2
Error messages for gas units
If your unit is equipped with a gas connection, the following additional error
messages may occur. Please contact your RATIONAL Service Partner [} 66]
regarding all error messages. Always have the serial number for your unit at the
ready.
Error message
Service 32.1
Service 32.2
Service 32.3
Service 33.1
Service 33.2
Service 33.3
72 / 84
Cause
An error occurred in the
water level detection
mechanism during automatic
cleaning.
Cause
The gas burner is
malfunctioning.
Close the locking mechanism
on the gas line.
The gas burner is
malfunctioning.
Close the locking mechanism
on the gas line.
The gas burner is
malfunctioning.
Close the locking mechanism
on the gas line.
The gas burner is
malfunctioning.
Close the locking mechanism
on the gas line.
The gas burner is
malfunctioning.
Close the locking mechanism
on the gas line.
The gas burner is
malfunctioning.
Close the locking mechanism
on the gas line.
Cooking possible
No
Cooking possible
No
No
No
No
No
No
Original user's manual