operations necessary for the configuration of a single loop, however, it is implicit that the operations be repeated for each of the
two loop.
Loop Card
B
Loop 1
C
Diagnostics
D
Parameters
E
Auto-configure
L: 2
Loop1: Loop1
Terminal Loop O: OK
Terminal Loop I: OK
Loop current sink (mA): 15
LOOP CLOSED
F
H
I
Loop reset
Scan
L: 2
001
002
003
004
005
013
023
024
025
K
Update
L: 2
[A]
Change Address
[B]
Section on the left for the loop connected to the Loop-A terminals, on the right for the Loop-B terminals.
[C]
Diagnostics
[D]
Parameters
[E]
Auto-configure
12
A
Change Address
B
Loop 2
C
Diagnostics
D
Parameters
E
Auto-configure
Esc
01/01/2022
18:23
Enroll
Readdress
C
Update
Add/Modify
Generic: 1
Esc
Sensors: 44
IN Modules: 12
OUT Modules: 5
IN/OUT Modules: 0
Sounders: 3
G
Call points: 8
N. SN
1 010EE4D4
J
Show topology
Esc
2 010EE4E0
01/01/2022
18:23
3 010EE0AB Input Module
4 010C7CAC Call point
5 010E1CE0
J
6 010EE6F2
006
007
008
009
010
014
015
016
017
018
Esc
01/01/2022
18:23
Button to access the section for IFM2L module address assignment (paragraph 2.4 Modules
Sections containing the configuration menu of the single loops.
Button to access the section for the selection of the type of devices installed on the loop.
It provides a check box for option selection "4 wires" (if the cabling has been completed as a ring
Button to access the automatic loop-configuration procedure.
E
L
M
N
O
O
Type
Description
Delete
Optical
Optical Smoke Detector
Smoke Detec-
01
tor
Optical
Optical Smoke Detector
Smoke Detec-
02
tor
Add/Modify
Input module 01
Call Point 01
Program
Optical
Optical Smoke Detector
Smoke Detec-
03
tor
Optical
Optical Smoke Detector
Smoke Detec-
04
tor
Found: 72
N. SN
Type
Description
Optical
Optical Smoke
1
010EE4D4
Smoke
Detector 01
Detector
Optical
Optical Smoke
2
010EE4E0
Smoke
Detector 02
Detector
010EE0AB Input
3
Input module 01 010EE0AB
Module
Call
4
010C7CAC
Call Point 01
point
Optical
Optical Smoke
5
010E1CE0
Smoke
Detector 03
Detector
Optical
Optical Smoke
6
010EE6F2
Smoke
Detector 04
Detector
Procedure in progress
Procedure completed
Found: 73
1 Generic
44 Sensors
12 IN Modules
5 OUT Modules
0 IN/OUT Modules
3 Sounders
8 Call Points
L: 3
addressing).
Button to access the section for loop diagnosis.
circuit, as required by the fire control standards).
Tap on Ok to confirm and exit.
Fire detection and extinguishing system
N
SN
Type
Optical
010EE4D4
Smoke
Detector
Optical
010EE4E0
Smoke
Detector
Optical
Smoke
Detector
Optical
010E1CE0
Smoke
Detector
Optical
010EE6F2
Smoke
Detector
Esc
100%
Configuring the fire detection system