Pro Swim Unit Installation
®
Section 14
USING YOUR FASTLANE PRO
Two wireless transmitters are included with the Fastlane Pro shipment which are used to turn the unit On/
Off and adjust the speed of the swim current. Press and hold the On/Off button (middle power button) to
turn the unit on. Press and hold the faster button (up arrow) to increase the speed of the swim current. Press
and hold the slower button (down arrow) to decrease the speed of the swim current. Turn the unit off by
pressing and holding the On/Off button.
The hydraulic power unit controller is equipped with a built-in timer, shutting the unit off after 30 minutes.
The Fastlane Pro will "remember" the speed of the swim current at which it was turned off and will default
to that same speed when the unit is turned back on.
Section 15

GENERAL INFORMATION

Once installed, the Fastlane Pro will provide years of exercise and fun with minimal maintenance. Clean
the intake grills of leaves as needed and wipe down the stainless steel cylindrical base and grab rail with
warm water, a Scotch Brite pad, and brisk rubbing. Clean the acrylic housing with any typical non-ammo-
nia, non-abrasive kitchen cleanser. Periodically, check all electrical and ground wire connections and test
the GFCI circuit breaker for proper function.
It is important for the long-term operation of your Fastlane Pro that your pool water be properly balanced
and in accordance with normal pool industry standards. In addition, it is imperative that the Fastlane Pro be
bonded to the pool bonding grid.
Endless Pools is an industry leader in customer service, should you ever have questions or concerns about
your Fastlane Pro, please contact our Customer Service Department at 800-910-2714 (US), 0800-520-0196
(UK) or 610-497-4538 (Direct).
Section 16

SCHEDULED MAINTENANCE

16.1 Hydraulic Motor and Fluid Maintenance. We recommend the hydraulic motor, which is located in your
16.2 Grill Cleaning. Should you perceive a reduction in speed of your Fastlane Pro, it may be caused by a
16.3 Cold Weather Maintenance. At the end of the swimming season, it is recommended the Fastlane Pro
16.4 Use of Salt-chlorine generators. Placing a Fastlane Pro in a pool sanitized using a salt-chlorine gener-
43
swim unit and submerged underwater, be replaced after six years of usage. We also recommend chang-
ing the non-food grade, biodegradable vegetable oil and filter in the Power Unit after every 500 hours
of use.
reduction in water flow due to a blockage of the inlet assembly of the cylindrical base. Because the un-
derside of your Fastlane Pro will be drawing in water, it may occasionally become necessary to clean
the cylindrical base of any debris or leaves that may have been in your pool when the Fastlane Pro was
in operation. With the Fastlane Pro unit turned off, this is very easy to accomplish while in the pool.
Swim Unit be removed from the swimming pool and winterized. For specific instructions, please con-
tact our Customer Service Department at 800-910-2714 (US), or 610-497-4538 (Direct).
ator creates increased risk of a hydraulic system failure and oil leaks. Any Fastlane Pro placed in this
type of environment must be properly bonded, and water chemistry must be closely monitored. As
stated in our warranty, pH levels must be maintained between 7.4 and 7.8, total alkalinity between 80
and 120 ppm, salt chlorine levels below 4000 ppm, and total dissolved solids below 7000 ppm. Failure
to properly bond the Fastlane Pro or maintain proper water chemistry will void the warranty.
If you are using a salt-chlorine generator, please complete the following tasks:
• Remove and inspect your Fastlane Pro unit annually. Once removed, rinse the Fastlane Pro with fresh
water before storing for the off-season.
• Replace the underwater hydraulic motor and submersible hoses every two years.
• Ensure that the fluid level in your power unit is no more than one cup above the float level switch.
This simple procedure ensures that any oil leak is minimized