Page 1
I N S T A L L A T I O N G U I D E A N D U S E R ’ S M A N U A L Fa s t l a n e Po o l...
Page 2
IMPORTANT SAFETY INFORMATION IMPORTANT SAFETY INFORMATION SAVE THESE INSTRUCTIONS BEFORE INSTALLING OR USING THIS PRODUCT, READ AND WARNING FOLLOW ALL SAFETY INSTRUCTIONS. FAILURE TO DO SO CAN RESULT IN PROPERTY DAMAGE, INJURY, OR DEATH SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS WARNING PRODUCT IS NOT INSTALLED OR USED CORRECTLY CHILDREN SHOULD NEVER SWIM UNSUPERVISED...
Page 3
DANGER RISK OF ELECTRICAL SHOCK A GROUND FAULT CIRCUIT INTERRUPTER (GFCI) OR RESIDUAL CURRENT DEVICE (RCD) is required for this product. The Ground Fault Circuit Interrupter (GFCI) or Residual Current Device (RCD) is NOT provided with this product. One must be sourced locally and installed into the panel box by a licensed electrician when making the electrical connections to the spa equipment.
Page 4
DANGER TO REDUCE THE RISK OF DROWNING Prolonged immersion in high temperature water can cause hyperthermia. Hyperthermia occurs when the internal temperature of the body is several degrees higher than the normal 98.6°F (37°C). The symptoms of hyperthermia include dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include: Failure to perceive heat Failure to recognize the need to exit the water...
(Box labeled: Fastlane Pool, Skimmer Plumbing and start-up RECEIVING THE FASTLANE POOL Box with Teleweir Skimmer and Skimmer Housing [4302250]) The Fastlane Pool is shipped via UPS and contains at least 16 Qty 1 - Skim-Filter packages. Additional packages may be sent depending on the...
• Consider privacy when selecting a location. SITE AND POOL PREPARATION The surface that the Fastlane Pool is to be assembled on must be firm and level. The Fastlane Pool must be installed as level as possible, within 2"- 3" of level (from the highest point to the lowest point of the pool).
Page 8
(Fig. 5). Fig. 7 - Longer (9' x 17') Fastlane Pool Fig. 4 5. Feed the connected top tubes (Parts B and C) into the corresponding sleeves of the liner (Fig 8). Be sure to align...
THRU-WALL CONNECTIONS There are 2 thru-wall penetrations for you water quality system. There is a thru-wall fitting and a return thru-wall fitting. The provided fittings will come with 3 gaskets (2 rubber and 1 cork). Only two will be used in this application. One rubber gasket will be used on the inside of the pool and the cork gasket will be used on the outside of the pool.
6. Attach the hanging brackets to the skimmer-filter housing. Position the smaller face of the bracket onto the underside of SKIMMER ASSEMBLY the housing so that the pre-drilled holes are aligned. Use the 1. Unthread the locking ring from the body of the skimmer- provided stainless steel screws to attach.
The packaging can be collapsed and used as a protective surface upon which to assemble the Fastlane. The foam packing material can be used to wedge under the base to prevent it from tipping over.
Page 12
1 screw attaching the stainless steel reinforcing sup- port to the housing just above the 3 previous screws (Fig 22). 7. Carefully lay the Fastlane onto its front face. Run the Slide the Horizontal Grill back into place hydraulic hoses up the back of the upper housing.
Page 13
Fastlane with the provided 3/4" Machine Screws. The top small curves or a circle with a utility knife can be difficult. pair of screw holes in the back of the Fastlane should be It may be best to work in many small straight cuts for accu- aligned with the holes that are second from the top of the racy.
21. Once the Fastlane is installed in the pool, place the housing Turn the power off, remove the fill cap and oil filter, and add lid onto the housing and use the provided screws to attach.
Suction Pressure Fig. 33 Fig. 35 11. Cut the 50' length down to the appropriate lengths to 4. Place the heater controller-mounting clamp onto the mount- connect the suction side of the pump to the union at the ing board so that it is aligned with the holes closest to the skimmer thru-wall assembly and connect the pressure side power unit.
Water Quality System and gluing the plumb- ing parts. Different option packages require different plumbing and electrical configurations. Standard Fastlane Pool package with no heater A licensed electrician should make all electrical connections. Suction The standard package will require a two-wire (plus ground) 220 volt 30 amp GFCI Power Supply.
Unit. Slide the liquid tight fitting over the cord of the WQS pump with the compression nut end first. With the liquid tight Fastlane Pool Package with optional 55,000 BTU Gas or fitting still loose on the cord, push the threaded end of the fit-...
The Fastlane wireless controller transmits radio waves, similar Panel 1 to a garage door opener. Should the Hydraulic Power Unit (HPU) be placed too far away from the Fastlane Pool, the wire- Panel 4 less controller may not be able to perform its functions. To oper-...
30-minute The Fastlane delay. • Clean the intake grill of the Fastlane Swim Unit of leaves While the Off mode is engaged, the display will toggle as needed. between OFF and the water temperature.
Page 20
Pool Water Chemistry Nature 2 Installation • It is important for the long-term operation of the Fastlane that The Nature 2 purification system will be placed inside of the fil- the pool water be properly balanced and in accordance with ter cartridge.
Page 21
5. Store the pool and equipment Equipment Hutch) until the keypad display reads, “OFF.” It If the Fastlane Pool is to be left together (i.e. the pool has a will take an additional few seconds for the pump to actually security cover): turn off.
Fastlane Swim Unit with hanger from the WATER TEMPERATURE pool wall. Pull the Fastlane Swim Unit out of the pool care- In a heating cycle, the system first generates water flow through fully so as not to damage the pool liner fabric.
80 and 120 ppm. The total dissolved solids (TDS) must be no greater than 3,000 ppm). The term “original purchaser”, as used in this warranty, shall be deemed to mean the person for whom the Fastlane Pool was original- ly installed.
Need help?
Do you have a question about the Fastlane and is the answer not in the manual?
Questions and answers