16.5 Cathodic Protection Maintenance Program. The Fastlane Pro has been fabricated using the finest,
most durable materials and has been designed to meet the most stringent safety standards, including
VGB 2008. However, unbalanced water chemistry and salt chlorine generators can shorten the lives
of these materials if the unit has not been properly bonded. Endless Pools has provided a sacrificial
anode to draw any corrosion to itself and away from the Fastlane Pro. To maximize the life span of
your Fastlane Pro, it is imperative that the Fastlane Pro be properly bonded and the sacrificial anode be
replaced after is has given up half its mass. Endless Pools offers a Preventative Maintenance Program.
This program will automatically send you a "sacrificial anode" on a regular basis for a nominal charge
to help prevent product damage due to electrolysis. Enrollment in this program is recommended if
the Fastlane Pro is installed in a pool with a salt-chorine generator. Contact Endless Pools Customer
Service at 800-910-2714 to enroll in this program.
Section 17
FASTLANE PRO CONSIDERATIONS
• The Submerged Suction Outlet Model #29-19 (part #124011) is certified only for use with the Endless
Pool Fastlane Pro system. It may not be used in any other application.
• This Submerged Suction Outlet Model #29-19 (part #124011) may only be installed as described in this
manual. The Submerged Suction Model #29-19 (part #124011), is 19" in diameter and 29" long and is
constructed of 316L perforated stainless steel. It should be replaced after 25 years using a #2 Phillips
head screwdriver. It shall be marked with the following label: NSF VGB 2008 SUBMERGED SUCTION
29-19, #124011. FOR USE ONLY WITH Fastlane Pro SWIMMING MACHINE MANUFACTURED BY
ENDLESS POOLS, INC. LIFE: 25 YEARS, WALL ONLY. MAXIMUM FLOW FROM SINGLE 5 HP
POWER UNIT WITH GR33-11 GEAR PUMP PRESET TO MAXIMUM FLOW OF 4.8 GPM UTILIZ-
ING 16" DIAMETER OPEN FLOW PROPELLER. ENDLESS POOLS, INC. ANSI/APSP-16 2011
• The Submerged Suction Outlet Model #29-19 (part #124011) does not require routine service during the
year or as part of Endless Pool winterizing procedures.
• Do not use the Fastlane Pro if there is any evidence of damage or tampering. Call the Endless Pools Cus-
tomer Service Department at 800 910 2714 immediately. The Submerged Suction Outlet Model #29-19
(part #124011) must be secured as described in this manual before the Fastlane Pro is used again.
• Before each use verify that the Submerged Suction Outlet Model #29-19 (part #124011), including the
fasteners, is undamaged and has not been tampered with.
• A missing, broken, or cracked Submerged Suction Outlet Model #29-19 (part #124011) must be replaced
before using.
• A loose Submerged Suction Outlet Model #29-19 (part #124011) must be reattached or replaced before
using.
• Do not exceed the maximum allowable flow rate stated on the Submerged Suction Outlet Model #29-19
(part #124011).
• Do not increase the flow through the Submerged Suction Model #29-19 (part #124011) by increasing the
size of the pump.
• Please read and then keep these instructions for future reference.
Fastlane
Pro Swim Unit Installation
®
44
Need help?
Do you have a question about the FASTLANE PRO and is the answer not in the manual?
Questions and answers