Function Specifications - Omron SYSMAC CP1E-E20DR-A Datasheet

Cpu units
Hide thumbs Also See for SYSMAC CP1E-E20DR-A:
Table of Contents

Advertisement

Function Specifications

Function
Minimum cycle time
Cycle time
management
Monitoring the cycle time
High-speed
counter
inputs
Interrupt inputs
Inputs
Quick-response inputs
Normal
inputs
CPU Unit
built-in
functions
Pulse
outputs
(Models
with
transistor
outputs
Outputs
only)
PWM outputs
(Models with transistor outputs only)
Normal
outputs
Analog input
Built-in
analog
Analog output
Functions
I/O
supported
refreshing
by both
Expansion
Expansion
I/O Unit and
I/O Units
Load OFF function
Expansion
and
Unit
Expansion
Units
Expansion
Input response times
I/O Units
Expansion
Unit error detection
Units
Holding I/O memory when changing operating modes
Memory
management
Automatic backup to the backup memory
functions
(built-in EEPROM)
Peripheral
Peripheral bus (toolbus)
USB port
Serial port (N/NA-type only)
Host Link (SYSWAY) communications
No-protocol communications
Communic
ations
NT Link communications
Serial PLC Links
Modbus-RTU Easy Master function
Scheduled interrupts
Interrupt inputs
Interrupt
High-speed counter interrupts
CP1E-E@@D@-@ CP1E-N@@D@-@/NA20D@-@
Function description
Makes the cycle time consistent.
Monitors the cycle time.
High-speed pulses from devices such as a rotary encoder are counted.
High-speed pulse inputs
The counted values are stored in the Auxiliary Area.
Interrupt tasks can be executed when target is reached or by range comparison.
Input pulse frequency
The frequency of pulses input by the PRV instruction is measured.
measurement
Relevant interrupt tasks are executed during the cycle when the CPU Unit built-in inputs
turn ON or turn OFF.
Inputs can be read without being affected by cycle time.
Use the quick-response inputs to read signals shorter than the cycle time.
Cyclic
The CPU Unit's built-in I/O are cyclically refreshed.
refreshing
I/O
refreshing
Immediate
I/O refreshing by immediate refreshing instructions
refreshing
Input constants can be set for Basic I/O Units.
Input response times
The response time can be increased to reduce the effects of chattering and noise at input
contacts. The response time can be decreased to enable detecting shorter input pulses.
A pulse signal is output and positioning or speed control is performed with a servo driver
that accepts a pulse input.
Pulse control
Continuous mode for speed control or independent mode for position control can be used.
There are functions for changing to positioning during speed control and for changing the
target value during positioning.
Origin positioning
Origin searches and origin returns
Pulses for which the duty ratio (ratio between ON time and OFF time during one pulse
cycle) can be set are output.
All of the outputs on the CPU Unit's I/O can be turned OFF when an error occurs in RUN
Load OFF function
or MONITOR mode.
Convert analog signal into digital value range from 0 to 6,000.
Convert digital value range from 0 to 6,000 into analog signal.
Cyclic refreshing
The Expansion I/O Units and Expansion Units are cyclically refreshed.
Refreshing by IORF
I/O refreshing by IORF instruction
All of the outputs on Expansion I/O Units and Expansion Units are turned OFF (0000 hex)
when an error occurs in RUN or MONITOR mode.
The response time can be increased to reduce the effects of chattering and noise at input
contacts. The response time can be decreased to enable detecting shorter input pulses.
Errors in Expansion Units are detected. The CPU Unit is notified that the Expansion Unit
stopped due to an error.
The status of I/O memory can be held when the operating mode is changed.
The forced-set/reset status can be held when the operating mode is changed.
Automatic backup of ladder programs and parameter area to the backup memory
(built-in EEPROM)
For communications with programming device (CX-Programmer).
--
Host Link commands can be sent from a PT or a computer to read/write I/O memory, and
perform other operations for PLC.
I/O instructions for communications ports (TXD/RXD instructions) can be used for data
transfer with peripheral devices such as bar code readers.
I/O memory in the PLC can be allocated and directly linked to various PT functions,
including status control areas, status notification areas, touch switches, lamps, memory
tables, and other objects.
Up to ten words per Unit can be shared by up to nine CPU Units, including one Polling Unit
and eight Polled Units.
Note: Programmable Terminal (PT) cannot be connected.
Modbus-RTU commands are sent by the Modbus-RTU Master function. Modbus slaves,
such as inverters, can be easily controlled with serial communications.
Tasks can be executed at a specified interval (1.0 ms min., Unit: 0.1 ms).
Interrupt tasks are processed when the built-in input turns ON or OFF.
This function counts input pulses with the CPU Unit's built-in high-speed counter and
executes an interrupt task when the count reaches the preset value or falls within a preset
range (target value or zone comparison).
11