Section 1
Studying the V400-F

Connecting Peripheral Devices

Connect peripheral devices to the reader.
Always turn OFF the reader before connecting or disconnecting a peripheral device's cable.
Peripheral devices may be damaged if the cable is connected or disconnected with the power ON.
The connector (CN2) for the monitor is capped when the reader is shipped. The cap must be left on
those connectors that are not used to protect them from dust, dirt and static electricity.
Attach a ferrite core.
The ferrite core must
be located at least
10 mm away from the
base of the connector.
Programmable controller
Communication/
power cable
Power
supply
device
Recommended: OMRON
S8VS-03024
Programmable controller
Discrete I/O
Wiring method: p.73
Make sure that the
connector is oriented
correctly and not inserted
at an angle. Secure the
connector using the
screws on both sides of
the connector.
V400-F050/250/350
20
User's Manual
Main
Align the
marks.
V400-W23 (NPN type)
V400-W23P (PNP type)
Blue
Brown
RS-232C connector
(male)
RS-232C connector
Align the
marks.
When plugging in a
connector, push it with a
force of no more than
15 to 20 N.
Then, pull gently on the
cable (approximately
10 N) to make sure the
connector is securely
connected.
Monitor cable
V400-WM0
or
V400-W24 (NPN type)
V400-W24P (PNP type)
Brown
Blue
Recommended: OMRON
S8VS-03024
RS-232C connector
(female)
Make sure that the
connector is oriented
correctly and not inserted
at an angle. Secure the
connector using the
RS-232C connector
screws on both sides of
the connector.
Monitor
F150-M05L-2D
+24 V
0 V
Brown
Blue
PC
Communication/
power cable
Power
supply
device
PC