Reading Results; Monitor Display - Omron 2D CODE READER User Manual

2d code reader
Table of Contents

Advertisement

Section 1
Studying the V400-F

Reading Results

This section explains details of the read results.

Monitor Display

Explanation of reading results displayed on the monitor is given below.
There are four display methods: normal display, highlighting display, code quality
analysis display and communication display.
The desired display method can be set in the setting mode.
Display setting:
Normal Display
Normal screen
Reading status
The reading status is
displayed.
OK (blue):Reading is
NG (red): Reading has
• Error code contents
Error code
?E000
?E100
?E200
If reading has failed, it may be possible that the cause can be identified by checking the read image.
Highlighting Display
The screen is enclosed in a frame whose color that indicates the reading status.
Reading status
The reading status is
displayed.
OK (blue):Reading is
NG (red): Reading has failed.
V400-F050/250/350
26
User's Manual
p.52
completed
successfully.
failed.
2D code cannot be found, possibly due to uneven background. Check the work piece
surface and lighting condition.
2D code cell cannot be recognized correctly. Check the marking and lighting conditions,
and then perform teaching again.
Reading was not completed within the specified period of time. Check the work piece and
lighting condition, then perform teaching again.
Increase the reading timeout value.
p.53
completed
successfully.
Read data
The read data is displayed.
(Max. 208 characters =
8 lines × 26 characters)
An error code is displayed in case of
reading error.
Action
Read data
The read data is displayed.
(Max. 26 characters)
An error code is displayed in
case of reading error.

Advertisement