Omron 2D CODE READER User Manual page 43

2d code reader
Table of Contents

Advertisement

Section 2
Changing Reading Conditions
5.
Save the settings.
Select [Save] from [Setting Menu] to save the settings.
p.56
Setting item
Switch Function
1st Bank
2nd Bank
3rd Bank
4th Bank
5th Bank
Total Timeout
Switch Order
V400-F050/250/350
42
User's Manual
Settings
OFF*/ON
If [ON] is selected, the bank will be switched from one to
another as specified.
1st Bank:
Select the reading conditions to be switched.
#00 to #09 (*#00)
No reading condition will be selected if [None] is selected.
Other:
#00 to #09, None*
1000 to 9999 (9999*) Set the time at which reading is to be stopped following start of
bank switch retry in case of reading failure.
Select the reading condition switching method.
Auto*
The switching order is determined automatically based on the
frequency of use.
Fixed
Banks will be switched in the order they have been registered,
starting from [1st Bank].
Details

Advertisement

Table of Contents
loading

This manual is also suitable for:

V400-fV400-f050V400-f250V400-f350