Omron 2D CODE READER User Manual page 66

2d code reader
Table of Contents

Advertisement

GC
Function... Performs continuous reading.
"Number of read data digits" and "code quality" are output only if they
are set.
p.47
Input
G C
• When reading is successful
Output
Read data
• When reading has failed
N G Error Code
?
Data is output each time reading is executed.
SC
Function... Stops continuous reading.
This command is effective only when a continuous trigger is being
executed.
Input
S C
Output
O K
RD
Function... Outputs the previous send data. (Polling command)
Use this command to resend data that has been lost due to
communication error.
Input
R D
• When reading is successful
Output
Read data
• When reading has failed
N G Error Code
?
Communicating with PC and Programmable Controller
Section 5
V400-F050/250/350
User's Manual