Lens and light (for V400-F050 only)
Left-side light cable connector
To the light
C-mount type lens
Recommended lens: p.89
Light cable
Power
For V400-F050/250/350, a power supply device must be provided separately.
Wire the power supply independently of other devices. In particular, keep the
power supply wired separately from inductive loads.
Use a DC power supply with safety measures against high-voltage spikes (safety extra low-
voltage circuits on the secondary side). If UL recognition is required for the overall system, use
a UL Class II DC power supply.
Handling the Cable
After the connector is plugged in, do not apply a
force of more than 30 N to the connector in the
directions shown below.
Excessive force will damage the connector.
30 N max.
30 N max.
Align the projection on the light
cable is connector with the slot on
the connector of the reader.
Recommended light: p.86
Light
To the light
Use a power supply that meets the following requirements.
Output current
Power supply voltage
Recommended
Connect the brown wire to the positive (+) side of the power
supply and the blue wire to the negative (-) side.
(+) side
(-) side
When disconnecting a cable, hold the part of the
plug shown below and then pull it out straight.
30 N max.
Studying the V400-F
Right-side light cable connector
1.2 A min.
24 VDC ±10%
S8VS-03024
Brown
Blue
Hold this part.
V400-F050/250/350
Section 1
21
User's Manual