Optional brake chopper and resistor(s) for the ACS800-
01/U1
The nominal ratings for dimensioning the brake resistors for the ACS800-01 and
ACS800-U1 are given below at an ambient temperature of 40 °C (104 °F).
ACS800-01 type
Braking power
of the chopper
ACS800-U1 type
and the drive
P
brcont
(kW)
230 V units
-0001-2
0.55
-0002-2
0.8
-0003-2
1.1
-0004-2
1.5
-0005-2
2.2
-0006-2
3.0
-0009-2
4.0
-0011-2
5.5
-0016-2
11
-0020-2
17
-0025-2
23
-0030-2
28
-0040-2
33
-0050-2
45
-0060-2
56
-0070-2
68
Brake resistor(s)
Type
SACE08RE44
SACE08RE44
SACE08RE44
SACE08RE44
SACE15RE22
SACE15RE22
SACE15RE22
SACE15RE13
SAFUR90F575
SAFUR90F575
SAFUR80F500
SAFUR125F500
SAFUR125F500
2xSAFUR125F500
2xSAFUR125F500
2xSAFUR125F500
Resistor braking 163
R
E
R
(ohm)
(kJ)
44
210
44
210
44
210
44
210
22
420
22
420
22
420
13
435
8
1800
8
1800
6
2400
4
3600
4
3600
2
7200
2
7200
2
7200
P
Rcont
(kW)
1
1
1
1
2
2
2
2
4.5
4.5
6
9
9
18
18
18

Advertisement