Capacitors

The drive intermediate circuit employs several electrolytic capacitors. The lifespan
depends on drive loading and ambient temperature. Capacitor life can be prolonged
by lowering the ambient temperature.
It is not possible to predict a capacitor failure. Capacitor failure is usually followed
by a mains fuse failure or a fault trip. Contact ABB if capacitor failure is suspected.
Replacements for frame size R4 and up are available from ABB. Do not use other than
ABB specified spare parts.

Reforming

Reform (re-age) spare part capacitors once a year according to
with electrolytic DC capacitors in the DC link, Capacitor reforming instructions
(3BFE64059629 [English]).

LEDs

This table describes LEDs of the drive.
Where
RMIO board *
Control panel mounting
platform (with type code
selection +0J400 only)
* The LEDs are not visible in frame sizes R2 to R6.
LED
Red
Drive in fault state
Green
The power supply on the board is OK.
Red
Drive in fault state
Green
The main +24 V DC power supply for the control panel
and the RMIO board is OK.
Maintenance 103
Converter modules
When the LED is lit