Optional Brake Chopper And Resistor(S) For The Acs800-01/U1 - ABB ACS800 Series Hardware Manual

Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

160
Note: A resistor other than the standard resistor can be used provided that:
• its resistance is not lower than the resistance of the standard resistor.
WARNING! Never use a brake resistor with a resistance below the value specified
for the particular drive / brake chopper / resistor combination. The drive and the
chopper are not able to handle the overcurrent caused by the low resistance.
• the resistance does not restrict the braking capacity needed, that is,
where
P
U
R
• the heat dissipation capacity (E
above).

Optional brake chopper and resistor(s) for the ACS800-01/U1

The nominal ratings for dimensioning the brake resistors for the ACS800-01 and
ACS800-U1 are given below at an ambient temperature of 40 °C (104 °F).
ACS800-01 type
ACS800-U1 type
230 V units
-0001-2
-0002-2
-0003-2
-0004-2
-0005-2
-0006-2
-0009-2
-0011-2
-0016-2
-0020-2
-0025-2
-0030-2
-0040-2
-0050-2
-0060-2
-0070-2
Resistor braking
2
U
DC
P
max <
R
maximum power generated by the motor during braking
max
voltage over the resistor during braking, e.g.,
DC
1.35 · 1.2 · 415 V DC (when supply voltage is 380 to 415 V AC),
1.35 · 1.2 · 500 V DC. (when supply voltage is 440 to 500 V AC) or
1.35 · 1.2 · 690 V DC (when supply voltage is 525 to 690 V AC).
resistor resistance (ohm)
Braking power
of the chopper
and the drive
P
brcont
(kW)
0.55
0.8
1.1
1.5
2.2
3.0
4.0
5.5
11
17
23
28
33
45
56
68
) is sufficient for the application (see step 3
R
Brake resistor(s)
Type
SACE08RE44
SACE08RE44
SACE08RE44
SACE08RE44
SACE15RE22
SACE15RE22
SACE15RE22
SACE15RE13
SAFUR90F575
SAFUR90F575
SAFUR80F500
SAFUR125F500
SAFUR125F500
2xSAFUR125F500
2xSAFUR125F500
2xSAFUR125F500
R
E
P
R
(ohm)
(kJ)
(kW)
44
210
1
44
210
1
44
210
1
44
210
1
22
420
2
22
420
2
22
420
2
13
435
2
8
1800
4.5
8
1800
4.5
6
2400
6
4
3600
9
4
3600
9
2
7200
18
2
7200
18
2
7200
18
Rcont

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-01 seriesAcs800-u1 seriesAcs800-01-0001-2Acs800-01-0002-2Acs800-01-0003-2Acs800-01-0004-2 ... Show all

Table of Contents