Door Status; Door Array; Door Control; Macro Array - Bosch Solution 6000-IP Installation Manual

Hide thumbs Also See for Solution 6000-IP:
Table of Contents

Advertisement

Unlocked - Fire
5) When finished press [OK] or [MENU] to exit.
Outputs > Commands >

Door Array

This menu allows the master user and installer to view
door status of the doors in groups of 16. Doors will
continuously be updated during the display so that real
time status can be seen. The top two rows of the display
show the door number, the third row displays the door
status
L = Door Locked
U = Door Unlocked
O = Door Open
- = Disabled or Not Available
1) Enter [MENU] + [4] + [0] + [4] and use the up and
down arrows to select the door group to view. The
keypad will display the door array information for
doors 1 to 16.
0000000001111111
1234567890123456
LLLLL---UUUUO---
Press  OK or MENU
In the above example screen,
L = Doors 01 to 05 are Locked
O = Door 13 is Open
U = Doors 09 to 12 are Unlocked
- = Doors 06 to 08 and Doors 14 to 16 are Disabled or
Not Available
2) When finished press [OK] or [MENU] to exit.
Outputs > Commands >

Door Control

This menu allows you to operate the door, lock the door
or unlock the door.
The first step is to select the door which you wish to
control keeping in mind that you will only be presented
with a list of doors that you are authorised to control and
secondly, that you are a master user.
1) Enter [MENU] + [4] + [0] + [5].
2) Use the arrow keys to highlight the door you wish
to control, then press [OK].
Bosch Security Systems 10/22 BLCC615I
-
MENU 4-0-4
-
MENU 4-0-5
Solution 6000-IP
Installation Manual
Dr1 Door 1 Name
Dr2 Door 2 Name
Dr3 Door 3 Name
Press
OK or MENU

3) Use the arrow keys to highlight the door control
option required, then press [OK]. To abort press
[MENU].
Operate
Lock
Unlock
Press
OK or MENU

Selecting the operate function will operate the door for
the programmed unlock time only and then the door will
return to it's resting state.
Selecting the Lock or Unlock functions will for the door to
change state and remain in that state until a master user
changes the lock condition of the door back to the normal
state, or until a timezone linked to the door triggers.
Outputs > Commands >

Macro Array

This menu allows the master user and installer to view the
macro status (Macros 01 to 08). Macros will continuously
be updated during the display so that real time status can
be seen. The top two rows of the display show the macro
number, the third row displays the macro status.
T = TRUE
F = FALSE
- = DISABLED
1) Enter [MENU] + [4] + [0] + [6]. The keypad will
display the array for macros 01 to 08. Macros 09 to
16 are not available.
0000000001111111
1234567890123456
TF--------------
Press  OK or MENU
In the above example screen,
T = Macro 01 is True
F = Macro 02 is False
- = Macro 03 to 08 are Disabled or Not Available
2) When finished press [OK] or [MENU] to exit.
Output Programming
-
MENU 4-0-6
8-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cc615gwfCc615pb

Table of Contents