F E AT U R E S
Listed below are the main features of the Solution 6000-IP
Control Panel.
Individual Box Tamper Circuit Monitoring
Report Via Email (Internet)
Daylight Savings
Senior Watch
System Maintenance Interval Reminder
System Weekly Test Reminder
Area Inactivity Interval
Temporary PIN
Dual Reporting
Dual Redundant Reporting
Alarm Report Abort/Cancel Options
8 Programmable Holiday Calendars
16 Programmable Door Assignments
8 On-board Zones (Exp To 144 Zones)
Fire Alarm Verification
990 PIN Users
4 Supervised High Power Digital Outputs
1 Relay 2 Amp Form (C) Contact (Expandable to 32)
Supervised Siren Driver
Partitionable To 8 Areas
Supervised LAN Keypads (Maximum 16 Keypads)
Keyswitch Input
2000 Event History Log Memory
EMI / Lightning Transient Protection
Fully Menu Text Programmable
Programmable Via Solution Link Software (Remote/Direct)
Time Executed Functions
60+ Output Event Types
Exit Restart
Expansion Module Supervision
Remote Arming
IP Reporting Via CSV-IP, Conettix, SIA, MyAlarm
Bosch Security Systems 10/22 BLCC615I
O V E R V I E W
Zones
The Solution 6000-IP control panel provides up to 144
separate zones of protection.
determines the panel's response to open/short and
tamper conditions on the zone loop.
Areas
The control panel supports up to 8 separate areas. You
can assign all zones to a single area, or you can assign
each zone to a combination of different areas.
You can arm and disarm the control panel by area,
alternatively, you can arm and disarm several areas at the
same time.
Keypads
You can connect a maximum of 16 fully supervised
keypads to the control panel. The available current affects
the total number of keypads that you can connect without
the need to provide additional power supplies.
History Log
The control panel can store up to 2000 history events from
all 8 areas. All events are stored in the log, even if they are
programmed not to report via the on-board dialler.
You can view the control panel's history log via keypad,
serial printer (optional), or by connection of a personal
computer (direct/remote) using the Solution Link upload/
download software.
Programming
You can program the control panel either by a keypad
or using a personal computer using the Solution Link
upload/download software.
S E C TIO N 1

Overview

Zone programming