Part On Arming Allowed; Disarming Allowed; Single Button Control; All User Areas - Bosch Solution 6000-IP Installation Manual

Hide thumbs Also See for Solution 6000-IP:
Table of Contents

Advertisement

Solution 6000-IP
Installation Manual
All On Arming Allowed
Selecting this option allow the user to turn the area All
On that the keypad or LAN reader is assigned to when
a valid PIN, token or fingerprint is presented. The user
must have access to the area that the keypad or LAN
reader has been assigned to. See MENU 6-1-3 — Home
Area.

Part On Arming Allowed

Selecting this option allows the user to turn the area Part
On or Part 2 On that the keypad or LAN reader is assigned
to when a valid PIN, token or fingerprint is presented.
To Turn Area All On Via Token
From the disarmed state, present the token once to turn
the area All On.
To Turn Area Part On Via Token
Present the token twice within 5 seconds to turn the area
Part On.
To Turn Area Part 2 On Via Token
Present the token three times within 5 seconds to turn
the area Part 2 On.
The control panel simultaneously supports both All
i
On and Part On functions for fingerprint readers by
Note
selecting both Option 1 and Option 2 in this menu.
However, this simultaneous support cannot be used
when the fingerprint reader has been programmed
with badging. See below for correct operation.
All On
To turn an area All On, present your finger and remove
when the reader vibrates indicating a successful read.
To turn the area off, present your finger and remove
when the reader vibrates indicating a successful read.
Part On
To turn the area Part On, present your finger and
remove 2 seconds after the reader vibrates indicating
a successful read.

Disarming Allowed

Selecting this option allows the user to turn off (disarm)
the area that the keypad or LAN reader is assigned to
when a valid PIN, token or fingerprint presented. The
user must have access to the area that the keypad or LAN
reader has been assigned to. See MENU 6-1-3 — Home
Area.
10-4
Device Programming

Single Button Control

This option allows single key arming (All On or Part On)
and single key disarming (from Part On or Part 2 On)
when using the keypad. Refer to programming areas for
respective options set per area.

All User Areas

This option allows the user to turn on or off all areas that
the user has been assigned to at the same time when
they swipe their token or fingerpint. At the keypad, the
user would simply enter their PIN and then press and
hold the [ON], [PART] or [OFF] keys to turn on or off all
areas they belong to.
Non Badging
Area Is All On
Present Finger Once
Area Is Part On
Present Finger Once
Area Is Off
Present Finger Once
Present Finger and Hold
Table 26: Fingerprint - Non Badging Examples
Badging Allowed
Area Is All On
Present Finger Once
Area Is Part On
Present Finger Once
Area Is Off
Present Finger Once
Present Finger and Hold
Table 27: Fingerprint - Badging Examples

Zero Exit Time

Selecting this option allow the user to turn the area All
On or Part On/Part 2 On from the keypad or LAN reader
with no exit time.
Open Door +
=
Turns Off All User Areas
Open Door +
=
Turns Off All User Areas
Open Door +
=
Turns On All User Areas
Opens Door +
=
Turns Part On All User Areas
Open Door +
=
Turns Off All User Areas
Open Door +
=
Turns Off All User Areas
=
Open Door
Opens Door +
=
Turns On All User Areas