Battery Test On Arming
Setting this option will cause the panel to perform an
additional dynamic battery test each time Area 1 is
armed All On.
OK To Arm Low Battery
Setting this option will allow the system to be armed
even though the panel currently has a low battery
condition.
When this option is disabled, the panel will not arm
if there is a low battery condition or if the battery is
missing. The user will be notified of the system trouble
on the keypad and they will need to have the fault
rectified before the system or area can be armed.
System > Power >
Fuse Options
1
Display COMM+ O/Load
2
Report COMM+ O/Load
3
Display +12v O/Load
4
Report +12v O/Load
5
Display LAN O/Load
6
Report LAN O/Load
7
Reserved
8
Reserved
(*** System Wide Parameter ***)
This menu option allows you to configure the Fuse related
system options.
1) Press [MENU] + [7] + [3] + [2]. The keypad will
display the current Fuse Options.
 Display COMM+ O/Load
 Report COMM+ O/Load
 Display +12v O/Load
Press  OK ON OFF MENU
2) Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Display COMM+ O/Load
Setting this option allows the keypad to display a system
trouble message when the current load on the COMM +
terminal exceeds its maximum rating of 3 Amps.
Report COMM+ O/Load
Setting this option will cause the panel to send an
Overcurrent Trouble report to the base station when
the current load on the COMM + terminal exceeds its
maximum rating of 3 Amps.
Bosch Security Systems 10/22 BLCC615I
Display +12v O/Load
Setting this option allows the keypad to display a system
trouble message when the current load on the +12 V
terminal exceeds its maximum rating of 1Amp.
Report +12v O/Load
Setting this option will cause the panel to send an
Overcurrent Trouble report to the base station when the
current load on the +12 V terminal exceeds its maximum
rating of 1Amp.
Display LAN O/Load
Setting this option allows the keypad to display a system
trouble message when the current load on the LAN+
terminal exceeds its maximum rating of 1Amp.
Report LAN O/Load
Setting this option will cause the panel to send an
Overcurrent Trouble report to the base station when the
MENU 7-3-2
current load on the LAN+ terminal exceeds its maximum
Y
rating of 1Amp.
Y
Y
H O R N S P E A K E R O P T I O N S
Y
Y
System > Siren >
Y
Tone
N
This menu allows you to customise the tone that is
N
emitted from the horn speaker when a non-fire alarm is
triggered. By changing the tone and speed, it is possible
to program a unique siren sound for each system when
you are installing a number of them in close proximity to
each other.
1) Press [MENU] + [7] + [4] + [0]. The keypad will
2) Use the up and down arrow keys to change the the
3) To test the new siren tone press [ON] to sound the
4) Repeat Steps 2 and 3 until the desired siren tone is
i
Note
Solution 6000-IP
Installation Manual
display the current siren tone.
Tone
1. . . . . . . . . . . . . 7
-------------  ---------
Press  OK to SAVE
siren tone.
siren and press [OFF] to turn the siren off.
achieved then press [OK] to save and exit, or press
[MENU] to exit without saving.
Only outputs programmed as Event Type 36 and or
37 will be affected by this menu option.