This feature only applies if your system reports to a
pocket pager. Basic pager reporting requires some
interpretation of the numbers that appear on the
display. It is possible to differentiate between 1000
different systems when a number of control panels
report to the one pocket pager.
Subscriber ID Number
This is the identification number of the control panel.
Only your installer can program this number.
Zone Status
The zone status display shows the status of each zone
(1 to 8). Table 12 describes each number of the zone
status display.
Table 12: Zone Status Display Descriptions
Display
Zone Description
0
Normal. The corresponding zone is sealed.
1
Alarm. The corresponding zone is unsealed
and in alarm.
2
Bypassed. A system operator manually
isolated the corresponding zone. Refer to
Section 9.0 Isolating Zones for information
about manually isolating a zone(s) before
arming the system.
3
Trouble. A zone was unsealed when exit time
expired.

System Status

The system status information is divided into the four
digits identified in Table 13.
Table 13: System Status
Digit
Description
First
8 = the system is disarmed
9 = the system is armed
Second
Identifies the codepad alarm activated by the
operator:
0 = No Codepad Alarm
1 = Codepad Panic or Duress Alarm
2 = Codepad Fire Alarm
3 = Codepad Medical Alarm
Third
0 = AC Supply is normal
1 = AC Supply failed
Fourth
0 = System Normal – There are no faults.
1 = System Fault – The control panel
registered a fault.
Figure 6 shows a transmission from a control panel
with an ID number of 678, and Zone 2 in alarm.
Figure 6 also shows Zone 3 is manually isolated and
the system is armed.
16
Basic Pager Reporting
Bosch Security Systems | 7/05 | F01U009494B