O: Keypad-Related Settings; O1: Keypad Display - YASKAWA GA500 GA50U Series Programming Manual

Table of Contents

Advertisement

1.13 o: Keypad-Related Settings

1.13

o: Keypad-Related Settings

o1: Keypad Display

No.
Name
(Hex.)
o1-01
User Monitor Selection
(0500)
RUN
o1-02
Monitor Selection at Power-
up
(0501)
RUN
o1-03
Frequency Display Unit
Selection
(0502)
o1-04
V/f Pattern Display Unit
(0503)
o1-05
LCD Contrast Adjustment
(0504)
RUN
o1-10
User Units Maximum Value
(0520)
o1-11
User Units Decimal Position
(0521)
o1-24
Custom Monitor 1
(11AD)
RUN
o1-25
Custom Monitor 2
(11AE)
RUN
o1-26
Custom Monitor 3
(11AF)
RUN
o1-27
Custom Monitor 4
(11B0)
RUN
o1-28
Custom Monitor 5
(11B1)
RUN
o1-29
Custom Monitor 6
(11B2)
RUN
98
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the U monitor for the Drive Mode. This parameter is only available with an LED keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the monitor item that the keypad screen shows after you energize the drive. Refer to "U:
Monitors" for information about the monitor items that the keypad screen can show. This parameter is
only available with an LED keypad.
1 : Frequency Reference (U1-01)
2 : Direction
3 : Output Frequency (U1-02)
4 : Output Current (U1-03)
5 : User Monitor (o1-01)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the display units for the frequency reference and output frequency.
0 : 0.01 Hz
1 : 0.01% (100% = E1-04)
2 : Revolutions Per Minute (RPM)
3 : User units (Set with o1-10, o1-11)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the setting unit for parameters that set the V/f pattern frequency.
0 : Hz
1 : min
-1
(r/min) units
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the contrast of the LCD display on the keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the value that the drive shows as the maximum output frequency.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the number of decimal places for frequency reference and monitor values.
0 : No Decimal Places (XXXXX)
1 : One Decimal Places (XXXX.X)
2 : Two Decimal Places (XXX.XX)
3 : Three Decimal Places (XX.XXX)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-
35. This parameter sets the user monitor to show on the first line. The registered monitor is also used
for different monitor displays of bar graph, analog meter, and waveform.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-
35. This parameter sets the user monitor to show on the second line. The registered monitor is also
used for different monitor displays of bar graph and waveform.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-
35. This parameter sets the user monitor to show on the third line. The registered monitor is also used
for the monitor display of the bar graph.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-
35. This parameter sets the user monitor to show on the fourth line.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-
35. This parameter sets the user monitor to show on the fifth line.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-
35. This parameter sets the user monitor to show on the sixth line.
Description
YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING
Default
(Range)
106
(104 - 855)
1
(1 - 5)
Determined by A1-02
(0 - 3)
Determined by A1-02
(0, 1)
5
(0 - 10)
Determined by o1-03
(1 - 60000)
Determined by o1-03
(0 - 3)
101
(0, 101 - 999)
102
(0, 101 - 999)
103
(0, 101 - 999)
0
(0, 101 - 999)
0
(0, 101 - 999)
0
(0, 101 - 999)

Advertisement

Table of Contents
loading

Table of Contents