12.3
Performance
Recommended measuring range
Version
LR510
Threaded connection
anntenna
LR530
Flanged encapsulated
PTFE antenna
LR550
Polymeric horn anten‐
na
LR580
Lens antenna
Measurement Accuracy (measured in accordance with IEC 60770-1)
Maximum measured error
Frequency
Minimum detectable distance
Update time
Influence of ambient temperature
Dielectric constant of material measured
Repeatability
Resolution
From minimum detectable distance to 30 m (98.4 ft) range, digital value, frequency mode
1)
1
+/- 10 mm (0.39 in) from reference point to 250 mm (9.84 in) distance
2)
From sensor reference point: see Dimensions (Page 187).
3)
Current output damping, number of shots averaging, fill & empty rate limit settings all
4)
reduce response time
SITRANS LR500 series with mA/HART
Operating Instructions, 03/2024, A5E51099898-AA
Size
Beam an‐
gle
G¾"
14°
¾" NPT
G1"
10°
1" NPT
G1½"
10°
1½ NPT (250 °C)
G1½"
7°
1½ NPT (150 °C)
≥ DN 25
10°
≥ DN 50, 2"
6°
≥ DN 80, 3"
3°
DN 80
3°
≥ DN 80, 3"
3°
= 1 mm (0.04")
peatability
W band, 80GHz nominal
Frequency modes 1, 2, 4
Frequency mode 3
3 measurements per second
Temperature drift
Digital output < 3 mm/10 K, max. 5 mm (0.2 in) over
the full operating range
dK > 1.6
0.5 mm (0.02 in)
0.5 mm (0.02 in)
Technical specifications
12.3 Performance
Recommended measur‐
ing range up to
10 m (32.81 ft)
20 m (65.62 ft)
30 m (98.42 ft)
30 m (98.42 ft)
20 m (65.62 ft)
30 m (98.42 ft)
120 m (393.7 ft)
120 m (393.7 ft)
120 m (393.7 ft)
including hysteresis and non-re‐
1) 2) 3)
liquids: 0 m (0 ft)
liquids: 0.25 m (0.82 ft)
4)
Permitted use
Tank only
Tank only
Tank only
Tank/ open air
Tank only
Tank/ open air
Tank/ open air
Tank/ open air
Tank/ open air
171