Temperature Units (2.2.2); Fill Rate Limit (2.2.3) - Siemens SITRANS LR500 Series Operating Instructions Manual

Radar level transmitters
Table of Contents

Advertisement

 
Setting
Default
Note
Dynamic decimal places
Each setting for parameter "Units" has a default number of decimal places used to show the
process value on the local display. However, if the value is too large to show on the segment
display, the decimal places will be automatically adjusted to show the process value.
Note
Process value too large to display
In some cases, even with dynamic decimal places, it is possible that the process value will be too
large to show on the local display, "#####" shows instead.
If this occurs in a typical application:
• Adjust parameter "Units" so that a smaller value can be shown, e.g. use meters instead of
millimeters.
If this occurs in a custom application:
• Adjust parameter "Custom units" so that a smaller value can be shown, e.g. use tons instead
of pounds.
• Note that a change to custom units also requires a scaling adjustment (see Custom units
(Page 75)).
9.2.2.2

Temperature units (2.2.2)

Sets temperature units used by the device.
Setting
Default
9.2.2.3

Fill rate limit (2.2.3)

Sets the maximum fill rate the device can track.
SITRANS LR500 series with mA/HART
Operating Instructions, 03/2024, A5E51099898-AA
Meters
Centimeters
Millimeters
Feet
Inches
Meters
°C (degrees Celcius)
K (Kelvin)
°F (degrees Fahrenheit)
°R (degrees Rankine)
°C (degrees Celcius)
Parameter assignment
Default
m
3 decimal places
cm
1 decimal place
mm
0 decimal places
ft
3 decimal places
in
2 decimal places
m
3 decimal places
9.2 Setup (2)
117