Logging Value 1 (3.6.5); Simulation (3.7); Simulation Mode (3.7.1) - Siemens SITRANS LR500 Series Operating Instructions Manual

Radar level transmitters
Hide thumbs Also See for SITRANS LR500 Series:
Table of Contents

Advertisement

Note
Log entries not immediately visible using "Overwrite oldest"
When setting "Overwrite oldest" is used, 30 log entries must be stored internally before any are
visible in the Trend log.
For example, to log Level and Sensor temperature every 10 minutes, it will take 2.5 hours for the
first log entries to appear.
Number of logging values = 2
Logging interval = 600
Logging behavior = Overwrite oldest
Logging value 1 = Level
Logging value 2 = Sensor temperature
The Trend log will appear empty until the first 30 entries (15 Level + 15 Sensor temperature) are
stored internally, then written to the log:
• A total of 30 log entries required, divided by the Number of logging values (2), stored at a
Logging interval of 600 seconds (10 minutes)
30/2 * 10 = 150 minutes or 2.5 hours
9.3.6.5
Logging value 1 (3.6.5) ... Logging value 8 (3.6.12)
Sets value to log.
Setting
Default
To edit the logging values, trend logging must be disabled.
9.3.7

Simulation (3.7)

9.3.7.1

Simulation mode (3.7.1)

Defines whether the simulated value is fixed or in the shape of a ramp.
SITRANS LR500 series with mA/HART
Operating Instructions, 03/2024, A5E51099898-AA
Level
Space
Distance
Echo signal strength
Confidence
Volume
Custom
Electronics temperature
Loop current
Distance
Echo strength
Parameter assignment
9.3 Maintenance and diagnostics (3)
141