Technical Specifications; Power; Performance; Interface - Siemens 7ML5202 Operating Instructions Manual

Ultrasonic transmitters
Table of Contents

Advertisement

Technical specifications

Note
Siemens makes every attempt to ensure the accuracy of these specifications but reserves the
right to change them at any time.
8.1

Power

12 to 30 V DC (at terminal blocks), 0.1 A surge
loop current
8.2

Performance

Range
Beam angle
Temperature
compensation
8.3

Interface

Display
Programming
Memory
32
4 to 20 mA max
0.25 to 5 m ( 0.8 to 16.4 ft ) (liquids only)
12° at -3 dB boundary
built-in to compensate over the operating range
liquid crystal
three 9 mm (0.35") digits for reading of distance between sensor face and material
multi-segment graphic for commissioning and troubleshooting
2 tactile buttons
non-volatile EEPROM, no battery required
Operating Instructions, 09/2021, A5E37100674-AB
8
SITRANS LU180

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans lu180Sitrans l

Table of Contents