Technical Specifications; Power; Performance - Siemens SITRANS LR460 Operating Instructions Manual

Radar transmitters
Hide thumbs Also See for SITRANS LR460:
Table of Contents

Advertisement

Technical specifications

6.1

Power

100 to 230 V AC, ±15%, 50/60 Hz, 6 W
24 V DC, +25/-20%, 6 W
Fuse (AC)
Fuse (DC)
6.2

Performance

Reference operating conditions according to IEC 60770-1
Measurement Accuracy (measured in accordance with IEC 60770-1)
Analog Output Accuracy (measured in accordance with IEC 60770-1)
Frequency
Measurement range
Long-term stability
Near Range (blanking)
Update time
Beam angle
Memory
Referenced from flange face.
1)
38
ambient temperature
humidity
ambient pressure
non-linearity (accuracy)
non-repeatability
deadband (resolution)
hysteresis error
non-linearity (accuracy)
non-repeatability
deadband (resolution)
1)
3" horn:
4" horn:
non-volatile EEPROM
no battery required
SI1 Fast acting ceramic, 4 x 20 mm, 1 A, 250 V AC
SI2 Slow-Blow, 4 x 20 mm, 0.63 A, 250 V AC
SI1 Fast acting ceramic, 4 x 20 mm, 2 A, 250 V AC
SI2 Slow-Blow, 4 x 20 mm, 0.63 A, 250 V AC
+15 to +25 °C
45 to 75% relative humidity
860 to 1060 mbar (12.47 to 15.37 psi)
greater of 25 mm (1") or 0.25% of span (including hysteresis
and non-repeatability)
10 mm (0.4") [included in non-linearity specification]
10 mm (0.4") [included in non-linearity specification]
0 mm
0.100% of span (including hysteresis and repeatability)
0.030% of span (included in non-linearity specification)
0.030% of span [included in non-linearity specification]
25 GHz nominal
0.35 to 100 m (1.15 to 328.08 ft)
≤ ± 1 mm/year
0.35 m (1.15 ft)
mA output and loop display is updated once per second
11° at –3 dB boundary
8° at –3 dB boundary
Compact Operating Instructions, 10/2021, A5E32007360-AB
6
SITRANS LR460

Advertisement