Description; Applications; Mode Of Operation And Diagnostics Leds; How To Use The Software Manual - Siemens SIMOVERT FC Series Operating Instructions Manual

Masterdrives cbc - communication board can-bus
Table of Contents

Advertisement

02.99
1

Description

1.1

Applications

The T100 technology board is a supplementary board in the SIMOVERT Master Drives 6SE70 and SIMOREG
DC MASTER series. It is possible to access all important signals and parameters of the technology board and
the basic converter via an additional communications board in the electronics box. The access mechanism and
the unit reactions of the T100 are identical to those of the SIMOVERT Master Drives basic converter unit.
The software module MS100 "Multi-Purpose Drive" extends the basic converter by a large number of drive-
related, process-oriented functions such as:
• Higher-level PID controller
• Comfort ramp-function generator
• Comfort motorized potentiometer
• Wobble generator
• 2 serial interfaces
• A large number of arithmetic, closed-loop control and logic blocks which can be freely interconnected by
means of parameterization.
1.2

Mode of operation and diagnostics LEDs

The T100 has a high-speed 16-bit microprocessor and its own parameter memory. The board is parameterized
via the basic converter unit, i.e. by means of the parameterizing unit PMU, the optional operator control unit OP1
or the SIMOVIS service program on a PC connected to the basic converter.
There are three diagnostic LEDs on the T100 board which indicate the following operating states:
• Middle, red LED flashing (3Hz):
• Bottom, yellow LED flashing (3Hz): Data exchange between T100 and the basic converter O.K.
• Top, green LED flashing (3Hz):
For a description of the board (connections, technical data, etc.), please refer to the "Hardware Operating
Instructions" for the T100 board (order no.: 6SE7080-0CX87-0BB0).
1.3
Virtually all the important hardware and software functions of the T100 are illustrated in the block diagram in
Chapter 2. Instructions on how to read this diagram are given in Chapters 3.1 and 10.
Start-up, faults and alarms are described in Chapters 6 and 8.
You can skip the other chapters initially and refer to them only when you need to find out more about a function,
a parameter or a connector.
Siemens AG 6SE7087-6CX84-0BB1
T100 Technology Board
Manual for Software Module MS100 "Multi-Purpose Drive"
T100 is operating fault-free in cyclic mode
(basic converter increments heartbeat counter correctly)
Data exchange between T100 and communications board O.K.
(communications board increments heartbeat counter correctly)

How to use the software manual