Test 11 Display of RPM calibration factor

Select test no. 11.
What to test:
The value is an indicator of the electronic RPM setting.
Target state:
Normally the factor is between 160 and 200.
The higher the value the stiffer the running of the machine,
and vice-versa.
Press clr to exit test and to return to service program basic position.
Repair notes:
Check machine for mechanical stiff-running.
Check cables and connectors for deformation and/or wear and tear.
Replace PCBA-Base
Replace PCBA-Power
Replace main motor.
Do not remove or plug in any connections when the sewing computer is switched on
or connected to the power supply.

Test 12 Start/Stop function

Select test no. 12.
Press foot control and keep pressed or press Start-/Stop
button.
What to test:
Endurance-test machine.
Target state:
Machine alternates between approx. 7 seconds running and approx. 7 seconds halt.
Press clr to exit test and to return to service program basic position.
BERNINA International AG · Seestrasse 161 · CH-8266 Steckborn · Switzerland
(Chapter 2 item 2.3
PCBA-Base).
(Chapter 4 item 4.2.4
PCBA-Power).