Mechanical fine-adjustment:
If electronic adjusting won't result in perfect matching of the lines, mechanical fine-adjusting is required:
Remove balance button.
Loosen screw 1 (T10).
Fine-adjust balance via pivot 2 (T10).
Retighten screw 1 (T10).
Refit balance button.

Test 3 Automatic darning program

Select test no. 3.
What to test:
Automatic darning (also buttonhole calibration test option).
Target state:
Lines of darning pattern must end on parallel, 'virtual' lines at
both ends.
If the virtual end lines are not parallel, balance and buttonhole
calibration must be checked.
Press clr to exit test and to return to service program basic position.

Test 4 Display of firmware version

Select test no. 4.
What to test:
Firmware version number appears in display.
For example: Version V 3.0.
Press clr to exit test and to return to service program basic position.