sensor-to-screen calibration: Workflow
Identify the recommended order for performing the sensor-to-screen calibration.
LiteLOC
sensor-to-screen calibration requires the following:
Spectroradiometer
Service user is the minimum level user access
Create a new calibration file (on page 54).
Recalibrate the calibration file (on page 55), if required.
Edit the existing calibration file parameters (on page 56) on the Sensor-to-screen menu, if
required.
Verify the calibration (on page 57), if required.
Add the calibration file to the Channel Setup (on page 57).

Creating a new calibration file

The Sensor-to-screen Calibration wizard guides you through the steps required to create a new
calibration file.
1. Set up a spectroradiometer to obtain screen measurements later in the process.
2. Select Menu > Color Settings > Sensor-to-screen Calibration.
3. To create a new calibration file, select Create
The projector checks if the light source is on and the douser is open. If either condition is not
met, a warning dialog is displayed prompting you to make sure these conditions are met
before starting the wizard.
4. In the Create dialog, enter a name for the new calibration file and select Create.
5. In step 1 of the Sensor-to-screen Calibration wizard, set the maximum brightness and color
point.
a) Enable the Display White Test Pattern option.
b) Adjust the RGB sliders to set the brightness and color point.
c) Select Next.
6. Wait 20 minutes for the projector to stabilize or select Skip during the stabilization time
period.
7. In step 2 of the Sensor-to-screen Calibration wizard, measure and enter the screen values.
a) To trigger the measurement at a specific operating point, under Sensor to screen, select
Capture.
The Capture button changes color to indicate the capture process is activated. Only one
Capture button is active at a time but the buttons can be selected in any order.
The projector automatically sets the red, green, and blue output laser powers to the pre-
determined settings calculated and displayed in the Drive Percentage (Calculated) area of
the wizard.
A 10 second countdown begins to allow the projector white point and brightness to
stabilize and no changes can be made. At the end of the count down period, the Color
Sensor values fields are automatically populated by the projector for the currently selected
drive percentage value.
CineLife+ User Guide
020-103073-10 Rev. 1 (02-2023)
Copyright
©
2023 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Managing the laser light source
.
54

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cinelife+ cp4415-rgb

Table of Contents