Automation

Use automation to control playback, the projector, and external devices.
Macros—A macro is a list of actions you define. For example, opening the curtains or turning
on the house lights at the end of playback. A macro can be activated by a global trigger or it
can be added to a playlist.
Device Input Triggers—Input cues wait for events, such as a general purpose input (GPI)
state change or an Ethernet message received on the projector management IP address port
5111. An input cue in a playlist delays playback until an event occurs.
Global Triggers—A global trigger combines an input cue with a macro. When the predefined
event for the input cue occurs, the output macro is triggered. For example, a fire alarm input
signal could cause playback to stop and the house lights to come on. A global trigger is always
active and is not dependent on specific playlist definitions.
On CP4450-RGB projectors, playback automation is controlled through the GDC Integrated Media
Block (IMB). For more information, refer to the documentation provided with your IMB device.
On CP44xx-RGB projectors, the GDC IMB automation cue ON_Projector does not function in Standby
mode. To automate your show, first use the Scheduler to power on the IMB.

Available macro actions

The following macro actions are available to control automated events.
Action item
Available actions
Automation
Set Global
Print
Get Global
Set GPO
Pulse GPO
Get GPI
Delay
Wait On GPI
Projector
Douser Open
Douser Close
Light
CineLife+ User Guide
020-103073-10 Rev. 1 (02-2023)
Copyright
©
2023 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Description
Sets a global variable to be used in automation scripting
(intended for advanced scripting by Christie).
Generates a projector log entry when an automation macro
runs.
Allows the automation script to read the value of a global
variable (intended for advanced scripting by Christie).
Sets the specified GPO pin to high or low.
Pulses the specified GPO pin.
Allows an automation script to read the GPI state (intended
for advanced scripting by Christie).
Delays macro execution.
Pauses the automation script and waits for the specified GPI
event to enter the specified state.
Opens the douser (shutter).
Closes the douser (shutter).
Turns the light on.