7.3 Cancelling the last alarm memorised

It is good practice to cancel the alarm code from the memory:
After reading the alarm, to check whether it is repeated during the diagnostics cycle.
After effecting repairs to the appliance, to check whether it is repeated during testing.
1. Start diagnostics mode.
2. Turn the programme selector in a clockwise direction to position ten.
3. Press the Start / Pause button and the button immediately to the left of it simultaneously.
4. Hold the buttons down for approximately 5 seconds.
5. After deleting, E00 will be displayed.

7.4 Notes about specific alarm codes

Configuration alarm E93:
When configuration alarms are displayed (when the appliance is switched on), the appliance is
inoperative and all the LEDs light. It is not possible to access diagnostics; the only operation
possible is to switch off the appliance (selector knob on position "0").
Alarms EH1-EH2-EH3:
In the event of problems with the power supply, the appliance remains in alarm mode until the
voltage and frequency are restored to within the normal limits or the appliance is switched off.
Alarm family "H" is displayed and it is not possible to access diagnostic mode nor to use the
"rapid alarm display" function.
The complete alarm can be read only when the abnormal condition has terminated.
Technical Support - A.D.L.