Motor; Asynchronous Three-Phase Or Inverter Motor Technical Details - Electrolux 6 Series Service Manual

Hide thumbs Also See for 6 Series:
Table of Contents

Advertisement

4.14 Motor

The asynchronous three-phase motor used in this tumble dryer has permanent magnets and is driver directly
by the inverter motor control board, which in turn receives commands from the main circuit board.
1
Fan.
2
Belt tensioner.
3
Motor.
4
Vibration damping bushes.
The motor unit consists of a belt tensioner (2) situated on an axis on the motor casing and secured by
a spring ring, with one fan (1) for the circulation of hot air, bolted to the motor shaft, of the motor (3) with
thermal cut-out and two vibration damping bushes (4) positioned on the two motor casings. The motor
power connector is located on a shaft fixed to a casing.
Calmed
2
4

4.14.1 Asynchronous three-phase or Inverter motor technical details

Power supply voltage
Frequency
RPM
Coil resistance 1 - 2
Coil resistance 1 - 3
Coil resistance 2 - 3
Technical Support - A.D.L.
3
230 V
50 Hz
2,700
20.4 Ω ± 7% at 20 °C
20.4 Ω ± 7% at 20 °C
20.4 Ω ± 7% at 20 °C
21/66
2
4
3
4
1
Z
U
Y
V
W
X
4
1
Yellow-green
Blue
Red
White
599 74 32-54 Rev.01