Electrolux 6 Series Service Manual page 52

Hide thumbs Also See for 6 Series:
Table of Contents

Advertisement

E5H
Input voltage is lower than 175 V
Input voltage is too high - greater
E5C
than 430 V
Data transfer error between inverter
E5d
and main PCB
Communication error between
E5E
inverter and main PCB
E5F
Inverter PCB fails to start the motor
Ex61
Compressor Hardware Failuew
Ex62
Compressor short-circuited
Ex63
Compressor alarm
Compressor "sensing" circuit faulty
Ex64
Ex65
VSC Safety Alarm
Technical Support - A.D.L.
Full name
 The cycle is suspended.
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 The cycle is suspended.
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 The cycle is suspended.
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 The cycle is suspended.
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 The cycle is suspended.
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 Stops cycle execution
 The drying cycle is suspended.
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 The drying cycle is suspended.
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 The cycle is suspended.
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 Stops cycle execution
Action
52/66
Notes and possible causes
 Faulty wiring.
 Inverter board faulty.
 Input voltage is too high (measure the grid
voltage).
 Inverter board faulty.
 Line interference.
 Faulty wiring.
 Main board or inverter board faulty.
 Faulty wiring between main board and inverter.
 Inverter board faulty.
 Main board faulty.
 Faulty wiring.
 Inverter board faulty.
 Main board faulty.
 VSC Board
 Compressor short-circuited.
 Compressor current leakage.
 Faulty wiring.
 Main circuit board faulty.
 Compressor disconnected (wiring or
connector error).
 Compressor thermal cut-out has triggered.
 Compressor faulty.
 Relay error (main board faulty).
 Error in the compressor detection circuit.
 Main board faulty.
----------------
599 74 32-54 Rev.01