Position 3
Anti-clockwise drum rotation
Position 4
Compressor cooling fan
Position 5
Clockwise drum rotation
Position 6
Compressor and clockwise
drum rotation
Technical Support - A.D.L.
Purpose of the test:
Components activated:
Behaviour:
Working conditions:
Purpose of the test:
Components activated:
Behaviour:
Working conditions:
Purpose of the test:
Components activated:
Behaviour:
Working conditions:
Purpose of the test:
Components activated:
Behaviour:
Working conditions:
24/66
To test the drum rotation motor in an
anti-clockwise direction.
Motor TRIAC.
Anti-clockwise direction relay.
Drum rotation motor.
Condensation water filling pump.
The motor turns the drum anti-clockwise and the
condensation water filling pump is in operation.
Door closed (time out 10 mins.).
Test operation of the compressor cooling fan.
Compressor cooling fan TRIAC.
Safety relay.
LCD indicates the position of the selector.
Door closed (time out 10 mins.).
To test clockwise rotation of the drum.
Clockwise drum rotation motor.
Safety relay.
LCD indicates the position of the selector.
The drying temperature NTC1 is displayed on
the LCD.
Door closed (time out 10 secs.).
To test compressor operation.
Compressor.
Clockwise drum rotation motor.
LCD indicates the position of the selector.
The drying temperature NTC1 is displayed on
the LCD.
Door closed (time out 10 secs.).