Electrolux 6 Series Service Manual page 25

Hide thumbs Also See for 6 Series:
Table of Contents

Advertisement

Position 7
Open-circuited conductivity
sensor
Position 8
Closed circuited conductivity
sensor
Position 9
Condenser Tank Switch
Technical Support - A.D.L.
Purpose of the test:
Components activated:
Behaviour:
Working conditions:
Purpose of the test:
Components activated:
Behaviour:
Working conditions:
Purpose of the test:
Components activated:
Behaviour:
Working conditions:
25/66
To check the conductivity sensor in open-circuit
conditions.
Conductivity sensor.
The test lasts 4 seconds, during which the LCD
flashes, displaying 000.
At the end of the test, the LCD stops flashing
and displays III.
If the test was unsuccessful, the LCD continues
to flash, displaying.
Conductivity sensor free from any garments or
contact.
To verify conductivity sensor in short circuit
condition.
Conductivity sensor.
The test lasts 4 seconds, during which the LCD
flashes, displaying 000.
At the end of the test, the LCD stops flashing
and displays III.
If the test is unsuccessful, the LCD displays the
alarm E32.
Short-circuited conductivity sensor.
Create a short circuit between the two sensors
on the front air conduit before setting the
selector dial to the eighth position.
To test the micro-switch under the condensation
water collection tray.
If the condensation water collection tray is full
and the micro-switch detects this condition, the
pump is started.
If the water level in the tray is low, the LCD
displays III and if the level is high (micro-switch
triggered), the LCD displays 000.
Door closed (time out 10 secs.).
599 74 32-54 Rev.01