10.3 Cancelling the last alarm memorized

It is good practise to cancel the alarm code from memory:
After reading the alarm, to check whether it is repeated during the diagnostics cycle.
After effecting repairs to the appliance, to check whether it is repeated during testing.
1. Turn the programme selector knob to the clockwise to the tenth position on models TC2 TC3 TC4
and to the eighth position on models TC6.
2. Hold down buttons 6 and 5 (about 5 seconds).
3. Once the alarm has been cancelled, E00 is displayed.

10.4 Notes concerning certain alarm codes

Configuration alarm E93: When configuration alarms are displayed (when the
appliance is switched on), the appliance is inoperative and all the LEDs light. It is not
possible to access diagnostics mode; the only possible operation is that of switching
off the appliance (selector knob on position "0").
Alarms EB1-EB2-EB3: In the event of problems with the power supply, the appliance
remains in alarm mode until the voltage and frequency are restored to within the normal
limits or the appliance is switched off (selector knob on position "0"). Alarm family "B" is
displayed and it is not possible to access diagnostics mode nor to use the "rapid alarm
display" function. The complete alarm can be read only when the abnormal condition has
terminated.