10.5 Deleting the last alarm

It is good practice to delete the alarm recorded:
after you have read it, to check whether or not it occurs again during diagnostic tests;
after repairing the appliance, to check whether or not it occurs again during testing.
1. Start diagnostics mode.
2. Turn the programme selector in a clockwise direction to position ten.
3. Press the Start/Pause button and the button immediately to the left of it simultaneously.
4. Hold the buttons for approximately 5 seconds.
5. After deleting, E00 will be displayed.

10.6 Notes on the behaviour of certain alarms

Configuration alarm E93: when these alarms are detected (on start-up) the machine will
stop and all the LEDs will light up: it will not be possible to access diagnostics mode and the
only available option is to turn the appliance off (selector set to position "0").
Alarms EH1-EH2-EH3: in the event of problems with the supply voltage, the machine will
remain in a state of alarm until the mains frequency or voltage returns to normal values or
until the appliance is turned off (programme selector set to "0"). The alarm family "H" is
displayed and the diagnostics mode cannot be accessed and the "quick alarm viewing" mode
cannot be used: the alarm can only be read in full when the situation has normalised.