9.3.3

Displaying other alarms

Press the START key to display all the other alarm conditions detected by the appliance. The alarms are
displayed in sequence.
9.3.4

Cancelling the last alarm

It is good practise to cancel all the alarm conditions stored in memory:
after reading the alarm, in order to check whether it re-occurs during the diagnostics routine.
after effecting repairs, to check whether it re-occurs during testing.
1. Access diagnostics mode (see relative
paragraph).
2. Turn the programme selector clockwise to the
tenth position.
3. Press START/PAUSE and the key immediately
to the left of the START/PAUSE key
simultaneously.
4. Hold both keys down for about 5 seconds.
5. When the alarms have been cancelled, the
display will show E00.
9.3.5

Notes concerning alarm conditions E93, EH1, EH2 and EH3

Configuration alarm - E93: If this alarm is detected (when the appliance is switched on),
operation is interrupted and all the LEDs light. It is not possible to access diagnostics mode.
The only operation that can be performed is to switch off the appliance (programme selector
on position "0").
Alarms EH1-EH2-EH3: In the event of power supply problems, the appliance remains in
alarm mode until the mains voltage and frequency are restored to the correct levels, or until
the dryer is switched off (programme selector on position "0"). The alarm family "H" is
displayed and it is not possible to access diagnostics mode nor to use the "rapid alarm
display" option. The complete alarm code can be read only when the abnormal condition has
been eliminated.