10.3 Rapid reading of the alarm codes

The last alarm code memorized can be displayed even if the appliance is in normal operating mode (e.g.
while the drying programme is being performed):
ð Press START/PAUSE and any one of the option buttons simultaneously for at least two seconds. The
LEDs switch off, then display the flashing sequence that identifies the alarm code.
ð The alarm sequence continues to flash as long as the two buttons are held down.
ð The reading system is as described in paragraph 10.2.1.
ð The appliance continues the cycle while the alarm codes are being displayed. If the appliance is in
programme selection mode, the options previously selected are stored in memory.

10.4 Cancelling the last alarm memorized

It is good practise to cancel the alarm code from memory:
After reading the alarm, to check whether it is repeated during the diagnostics cycle.
After effecting repairs to the appliance, to check whether it is repeated during testing.
1. Access diagnostics mode and turn the programme selector knob to the eleventh position (alarm
reading).
2. Press START/PAUSE and any one of the option buttons simultaneously.
3. Hold down the START/PAUSE and option buttons for about 5 seconds.

10.5 Notes concerning certain alarm codes

§
Configuration alarm E93: When configuration alarms are displayed (when the appliance is switched
on), the appliance is inoperative and all the LEDs light. It is not possible to access diagnostics mode; the
only possible operation is that of switching off the appliance (selector knob on position "0").
§
Alarms EB1-EB2-EB3: In the event of problems with the power supply, the appliance remains in
alarm mode until the voltage and frequency are restored to within the normal limits or the
appliance is switched off (selector knob on position "0"). Alarm family "B" is displayed and it is not
possible to access diagnostics mode nor to use the "rapid alarm display" function. The complete
alarm can be read only when the abnormal condition has terminated.