A.3
Conductive Rod Functional Check
Checking the function
The purpose of the following procedure is to verify the performance of the Conductive Rod.
To carry out this test the following are required:
• A Transmitter for generating the signal in the Sonde and Line mode tests
• The cable set for the Conductive Rod.
Insert the Conductive Rod's cable set into the Transmitter and Conductive Rod. Ensure the
black cable is connected. Switch the Transmitter on. The audible output from the Trans-
mitter must be constant. Adjust the signal output on the Transmitter to minimum, the
audible output must be constant. Part the black cable set in the middle, the audible output
must be pulsed.
If any of these tests give no response or a significantly different response from
normal, the Conductive Rod should be returned for service.
DIGICAT 500i/550i, Functional Checks
97