Pinpointing the service
• Always use chalk or paint to mark services, never pegs.
• The signal strength indicator does not indicate the size, depth or type of a service.
Peak hold
When activated peak hold will show the highest peak reading obtained during the pinpoint
process. The displayed reading can be adjusted between 0 to 5 seconds.
DIGICAT 500i/550i, How to Use the Locator
Hazard zone can be operated in Power, 8 kHz, 33 kHz and Auto modes and
provides an additional alarm to the presence of buried services which may be
within close proximity.
Retrace your steps to the area
where the highest signal reading
(peak response) was obtained.
The service is directly below the
Locator when the signal strength
indicator is at its maximum. The
audio output will automatically
adjust to facilitate pinpointing
over the service, and automati-
cally reset when the signal
strength indicator drops to its
minimum position.
21