Short-Circuit Protection
Leakage Handling
Electrolyte overflow may damage the equipment. It will corrode metal parts and
boards, and ultimately damage the boards.
Electrolyte is corrosive and can cause irritation and chemical burns. If you come
into direct contact with the battery electrolyte, do as follows:
Issue 02 (2024-01-05)
professional O&M personnel immediately to remove or replace the battery.
Do not store the damaged battery near other devices or flammable materials
and keep it away from non-professionals.
Before working on a battery, ensure that there is no irritating or burning smell
around the battery.
When installing batteries, do not place installation tools, metal parts, or
sundries on the batteries. After the installation is complete, clean up the
objects on the batteries and the surrounding area.
To safeguard against water intrusion and subsequent battery carbonization,
ensure that the bottom of a battery remains more than 10 cm above ground
level.
If a battery is accidentally exposed to water, do not install it. Move it to a safe
place for isolation and contact technical engineers in a timely manner.
Check whether the positive and negative battery terminals are grounded
unexpectedly. If so, disconnect the battery terminals from the ground.
Do not perform welding or grinding work around batteries to prevent fire
caused by electric sparks or arcs.
If batteries will not be used for a long period of time, store and charge them
according to the battery requirements.
Do not charge or discharge batteries by using a device that does not comply
with local laws and regulations.
Keep the battery loop disconnected during installation and maintenance.
Monitor damaged batteries during storage for signs of smoke, flame,
electrolyte leakage, or heat.
If a battery is faulty, its surface temperature may be high. Do not touch the
battery to avoid scalds.
When installing and maintaining batteries, wrap the exposed cable terminals
on the batteries with insulation tape.
Avoid foreign objects (such as conductive objects, screws, and liquids) from
entering a battery, as this may cause short circuits.
NO TICE
Inhalation: Evacuate from contaminated areas, get fresh air immediately, and
seek immediate medical attention.
Eye contact: Immediately wash your eyes with water for at least 15 minutes,
do not rub your eyes, and seek immediate medical attention.