Storage and handling
TONiC non-contact optical encoder systems provide
good immunity against contaminants such as dust,
fingerprints and light oils.
System
N-heptane
CH
(CH
)
CH
3
2
5
3
Propan-2-ol
CH
CHOHCH
3
3
8
TONiC
REXM20 / REXT20 angle encoder system installation guide
™
However, in harsh environments such as machine
tool applications, protection should be provided to
prevent ingress of coolant or oil.
Ring only
Acetone
CH
COCH
3
3
Methylated
Spirits
Readhead only
Acetone
Chlorinated
CH
COCH
Solvents
3
Methylated
Spirits
Chlorinated
Solvents
3