Renishaw TONiC DOP Installation Manual

Encoder system

Advertisement

Quick Links

Installation guide
M-9653-9278-01-D
TONiC
RSLM high accuracy linear encoder
DOP (dual output) encoder system

Advertisement

Table of Contents
loading

Summary of Contents for Renishaw TONiC DOP

  • Page 1 Installation guide M-9653-9278-01-D TONiC RSLM high accuracy linear encoder DOP (dual output) encoder system ™...
  • Page 2: Fcc Compliance

    Renishaw plc. The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or Disclaimer authorised representative could void the user’s authority to operate the equipment.
  • Page 3: Storage And Handling

    Storage and handling Readhead Readhead Interface N-heptane Acetone Chlorinated COCH Solvents Propan-2-ol Methylated CHOHCH Spirits Readhead Storage Operating Humidity +70 °C -20 °C +70 °C 0 °C Rated up to +40 °C, <95% relative humidity (non-condensing)
  • Page 4 readhead installation drawing (RELM/RSLM scale shown. For other scales, see relevant system installation guide) Dimensions and tolerances in mm Reference mark selector (Roll tol. ±0.5°) sensor position (Yaw tol. ±0.4°) Reference mark selector 0.08 (A-9653-0143) 0.25 P and Q limit switch (Only required for Alternative sensor position...
  • Page 5 DOP interface installation drawing quick-start guide Dimensions and tolerances in mm This section is a quick-start guide to installing a TONiC system. More detailed information on installing the system is contained in the following sections of the installation guide. INSTALLATION Ensure scale, readhead optical window and mounting faces are clean and free from obstructions.
  • Page 6: System Connection

    System connection Readhead mounting and alignment Approved ESD precautions must be followed at all times during Mounting brackets readhead and interface electrical connections. The bracket must have a flat mounting surface and should enable conformance The readhead is connected to the DOP interface via a small, to the installation tolerances, allow adjustment to the rideheight of the readhead, rugged connector to allow for easy feed-through and be sufficiently stiff to prevent deflection or vibration of the readhead during...
  • Page 7: System Calibration

    * -Alarm output will take the form of 3-state or line driven E signal depending on interface configuration. will flash several times, indicating that the factory defaults have been restored. Also, some configurations do not output overspeed alarm. See TONiC DOP Data Sheet (L-9517-9411) for details of interface configuration. Release CAL button.
  • Page 8: Electrical Connections

    Electrical connections Connections DOP output DOP system grounding and shielding Extension cable Customer max. 50m dependent Readhead Interface electronics on output frequency Inner shield Output signals 26 pin high density D type plug Outer shield Function Output type Signal Power 5 V Power 5 V Sense IMPORTANT: The outer shield should be connected to the machine earth (Field Ground).
  • Page 9: Output Specifications

    Output specifications Digital output signals Analogue output signals Form - Square wave differential line driver to EIA RS422A (except limits P and Q) NOTE: Analogue signals are also available direct from all TONiC readheads Incremental 2 channels V and V differential sinusoids in quadrature Incremental …...
  • Page 10: General Specifications

    Receiver clock Maximum frequency (MHz) cable length (m) 40 to 50 <40 analogue Renishaw encoder systems have been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential.
  • Page 11 RENISHAW and the probe emblem used in the RENISHAW logo are ® registered trademarks of Renishaw plc in the UK and other countries. apply innovation is a trademark of Renishaw plc. © 2010-2023 Renishaw plc All rights reserved...