Storage and handling

TONiC non-contact optical encoder systems provide good immunity against contaminants such as dust, fingerprints and light oils. However, in harsh environments such as machine tool applications,
protection should be provided to prevent ingress of coolant or oil.
System
N-heptane
CH
(CH
)
CH
3
2
5
3
Propan-2-ol
CH
CHOHCH
3
3
20
TONiC™ FS RELM20/ RSLM20 Functional Safety installation guide and safety manual
Scale only
Acetone
Chlorinated
CH
COCH
Solvents
3
3
Methylated
Spirits
Readhead only
Acetone
CH
COCH
3
3
Methylated
Spirits
Minimum bend radius
RELM20 - DO NOT BEND
RSLM20 - 250 mm
NOTE: Ensure self-adhesive tape is on
the outside of bend.
Chlorinated
Solvents