Chapter 5 – Configuration
Setting port parameters
RS232 Params Menu
The administrator should specify the communication protocols between ACS-9910 and the
external modem and between ACS-9910 and the remote terminal or terminal emulation
software. This is done in the Modem Port Menu located at Main Menu > RS232 Params
Menu > Modem Port Menu and the Terminal Port Menu located at Main Menu > RS232
Params Menu > Terminal Port Menu.
6 RS232 Params
6.1 Modem Port
6.2 Terminal Port*
Modem Port Menu
6.1
Modem port
Set the baud rate, Stop bit, data bit and parity parameters for the modem port to
match those of the modem (see modem product documentation).
6.1.1
Baud Rate
2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600 or 115200 (Default:
19,200)
6.1.2
Stop Bit
1 or 2 (Default: 1)
6.1.3
Data Bit
7 or 8 (Default: 8)
6.1.4
Parity
None, Odd or Even (Default: None)
Terminal Port Menu
6.2
Terminal Port
Set the baud rate, Stop bit, data bit and parity parameters for the terminal port to
match those of the host.
6.2.1
Baud Rate
2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600 or 115200 (Default:
19,200; Recommended: 115,200)
6.1.1 Baud Rate
6.1.2 Stop Bit
6.1.3 Data Bit
6.1.4 Parity
*submenus as Modem Port
2400 / 4800 / 9600 / 14400 / 19200 /
28800 / 38400 / 57600 / 115200
1 / 2
7 / 8
None / Odd / Even
47