5. Testing

Send and Monitor 511

The Send and Monitor 511 test sends a test pattern over the network interface that
causes the local and remote units to send a 511 test pattern to each other. The
front panel Test LEDs of both units are on during the test. The duration and results
of the test are displayed on the Network Tests screen of the unit that initiated the
test.
Local
NTU/LTU
Port
All 1s
Framer
Interface
Procedure
To run a Send and Monitor 511 test:
When a Send and Monitor 511 test is active, a count of bit errors is displayed next
to the test duration, and the ResetMon virtual function key is available for use.
Type r or R or select the ResetMon virtual function key to reset the error count.
5-6
511 Pattern
511
Gen
CAP
511 Pattern
511
Mon
1. Position the cursor at the Start command next to Send and Monitor 511 on the
Network Tests screen.
2. Press Enter.
The Start command is changed to Stop.
3. To manually stop the test, verify that the cursor is positioned at the Stop
command.
4. Press Enter.
February 2001